2023/06/26 12:00 | Decommisioned from service |
2023/06/23 17:10 | Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No Raw Read Error Rate = 1198, Seek Error Rate = 0, Multi Zone Error Rate = 20, UDMA CRC Error Count = 0 Self Tests = E✗S✗S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓ |
2023/06/23 15:26 | SMART Extended test with estimate 11:51:00: Done with read failure at LBA 2040206256 and remaining 80 % in 1:44:00 |
2023/06/23 15:26 | Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No Raw Read Error Rate = 1198, Seek Error Rate = 0, Multi Zone Error Rate = 0, UDMA CRC Error Count = 0 Self Tests = S✗S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓S✓ |
2023/06/23 02:44 | Loading... |
2023/06/23 02:44 | Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No Raw Read Error Rate = 833, Seek Error Rate = 0, Multi Zone Error Rate = 0, UDMA CRC Error Count = 0 Self Tests = S✗S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓S✓ |
2023/06/22 14:17 | Loading... |
2023/06/22 09:12 | Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No Raw Read Error Rate = 833, Seek Error Rate = 0, Multi Zone Error Rate = 0, UDMA CRC Error Count = 0 Self Tests = S✗S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓S✓ |
2023/06/21 11:51 | Drill: 30 x 0.00T-0.15T |
2023/06/20 10:09 | Current Pending Sector = 34, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No Raw Read Error Rate = 831, Seek Error Rate = 0, Multi Zone Error Rate = 0, UDMA CRC Error Count = 0 Self Tests = S✗S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓S✓ |
2023/06/19 21:25 | Loading... |
2023/06/19 17:39 | Current Pending Sector = 4, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No Raw Read Error Rate = 388, Seek Error Rate = 16, Multi Zone Error Rate = 0, UDMA CRC Error Count = 0 Self Tests = S✗S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓S✓ |
2023/02/16 12:00 | Removed from service |
Days in operation = 715 |
|
2021/03/03 12:00 | Returned to service |
2021/01/22 12:00 | Removed from service |
Days in operation = 2110 |
|
2015/04/14 12:00 | Start of service |