6 TB WDC WD60EFRX-68L0BN1
(serial number WD-WX31D9584EZ3)

Back   (Plot navigation: Left Mouse = Zoom, Up/Down Wheel or Left/Right Key = Pan, Right Mouse = Reset)

2021/11/03 12:00 Decommisioned from service

2021/10/31 14:59 Current Pending Sector = 2, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 10098, Seek Error Rate = 0, Multi Zone Error Rate = 8, UDMA CRC Error Count = 0
Self Tests = E✗E✓E✗E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✗E✓E✓S✓S✓S✓
2021/10/31 14:58 SMART Extended test with estimate 11:29:00: Done with read failure at LBA 2006276032 and remaining 90 % in 0:01:00
2021/10/31 14:58 Current Pending Sector = 2, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 10098, Seek Error Rate = 0, Multi Zone Error Rate = 8, UDMA CRC Error Count = 0
Self Tests = E✓E✗E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✗E✓E✓S✓S✓S✓S✓
2021/10/31 00:48
Loading...
2021/10/28 09:30 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 1569, Seek Error Rate = 0, Multi Zone Error Rate = 8, UDMA CRC Error Count = 0
Self Tests = E✓E✗E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✗E✓E✓S✓S✓S✓S✓
2021/10/27 21:29
Loading...
2021/10/27 11:26 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 1501, Seek Error Rate = 0, Multi Zone Error Rate = 8, UDMA CRC Error Count = 0
Self Tests = E✓E✗E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✗E✓E✓S✓S✓S✓S✓
2021/10/27 01:02 Drill: 30 x 1.10T-1.20T (4 read errors in cycle 1)
2021/10/26 10:58 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 55, Seek Error Rate = 0, Multi Zone Error Rate = 8, UDMA CRC Error Count = 0
Self Tests = E✓E✗E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✗E✓E✓S✓S✓S✓S✓
2021/10/25 22:55
Loading...
2021/10/25 22:47 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 13, Seek Error Rate = 0, Multi Zone Error Rate = 8, UDMA CRC Error Count = 0
Self Tests = E✓E✗E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✓E✗E✓E✓S✓S✓S✓S✓
2021/10/07 12:00 Removed from service

Days in operation = 1680
2017/03/02 12:00 Start of service

Back   (Plot navigation: Left Mouse = Zoom, Up/Down Wheel or Left/Right Key = Pan, Right Mouse = Reset)