2 TB WDC WD2003FYYS-02W0B0
(serial number WD-WMAY00576090)

Back   (Plot navigation: Left Mouse = Zoom, Up/Down Wheel or Left/Right Key = Pan, Right Mouse = Reset)

2023/07/29 04:51 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 0, Seek Error Rate = 0, Multi Zone Error Rate = 0, UDMA CRC Error Count = 0
Self Tests = E✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✗S✓S✓
2023/07/29 00:05 SMART Extended test with estimate 4:59:00: Done in 4:46:00
2023/07/29 00:05 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 0, Seek Error Rate = 0, Multi Zone Error Rate = 1, UDMA CRC Error Count = 0
Self Tests = S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✗S✓S✓S✓
2023/07/28 19:25
Loading...
2023/07/28 19:25 Current Pending Sector = 0, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 0, Seek Error Rate = 0, Multi Zone Error Rate = 1, UDMA CRC Error Count = 0
Self Tests = S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✗S✓S✓S✓
2023/07/28 14:45
Loading...
2023/07/26 16:25 Current Pending Sector = 1, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 0, Seek Error Rate = 0, Multi Zone Error Rate = 1, UDMA CRC Error Count = 0
Self Tests = S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✗S✓S✓S✓
2023/07/26 11:44
Loading...
2023/07/26 11:40 Current Pending Sector = 1, Offline Uncorrectable = 0, Reallocated Sector/Event Count = 0/0, Failing = No
Raw Read Error Rate = 0, Seek Error Rate = 0, Multi Zone Error Rate = 1, UDMA CRC Error Count = 0
Self Tests = S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✓S✓S✓S✓S✓S✓S✓E✗S✓S✓S✓
2023/07/12 12:00 Removed from service

Days in operation = 4149
2012/03/02 12:00 Start of service